TM 9-6115-670-14&P
5-100
d. Remove two nuts and flat washers (2, Figure 4-6), two rubber washers (3), two lock washers
and bolts (4) securing radiator (1) to radiator mount (5).
e. Remove one bolt, flat washer and lock washer (8, Figure 4-42) and ground strap (7) from
frame.
f. Remove four bolts, flat and lock washers (9, Figure 4-19) (JTACS and WIN-T), or four bolts and
flat washers (5, Figure 4-20) (SICPS) securing fuel day tank assembly to frame.
g. (JTACS and WIN-T) remove one bolt, flat and lock washer (31, Figure 5-24) and hex nut (33)
securing fuel hose clamp (32) to isolator mount.
h. Remove one screw, flat and lock washer (3, Figure 4-18) (SICPS) securing fuel pump bracket
(1) to generator mount (8), or one bolt, flat and lock washer, and spacer (JTACS and WIN-T)
securing fuel pump bracket (1) to isolator mount.
i. Remove four hex-head socket screws (20, Figure 5-24) and spacers (19) securing alternator to
isolator mount (JTACS and WIN-T only).
j. Secure lifting device to lifting eyes (5 and 6).
k. (SICPS) remove four bolts, flat and lock washers (5) securing APU (9) to resilient mounts (6).
l. (JTACS and WIN-T) remove two bolts, flat washers (26) and lock nuts (29) securing APU to
vibration isolator mount (28)
NOTE
Do not remove fuel pump assembly from fuel pump
bracket. Place hardware back on bracket after
removing bracket from frame/mount.
NOTES
The four spacers are located between frame and
alternator. They are not accessible until unit is
removed from frame.
Ensure 24 VDC to starter is disconnected (para
4.37.) and AC output is disconnected before
removing APU from frame assembly.
CAUTION
Prior to removing the bolts that secure the unit to the
frame, ensure the lifting device is attached to lifting
eyes in order to prevent damage to equipment or
serious injury to personnel.