TM 9-6115-647-14&P
(7)
Separate connectors P41 and J41 on generator set (6). Connect P12, J11 wiring harness (9)
to generator set by connecting P12 to J41 and J11 to P41, and to terminal board TB2 on
adapter plate assembly (3)
(Refer to figure 5-3 when reconnecting wires ).
(8)
Connect four J3 harness wires (8) to generator set load terminals as follows J3 pin A to
L1, J3 pin C to L2, J3 pin G to L3 and J3 pin E to L0.
(9)
Connect generator set ground wire (9 1) to generator skid ground Connect ground wire
(9 2) to adapter panel assembly GROUND.
(10)
Connect fuel line (5) to auxiliary fuel connection on generator set (6) Turn fuel selector valve
(4) to AUXILIARY
(11)
Plug P3 power/control cable (1) and P4, P7 low fuel cable (2) into connectors J3 and J4
respectively on the adapter plate assembly (3).
NOTE
If worm type hose clamps have already been installed on generator set fuel
tank lines, omit step (12).
(12)
Remove and discard eight spring type hose clamps from generator set fuel tank vent lines
(17), and replace with eight worm type hose clamps (16). Be careful not to over tighten hose
clamps.
(13)
Close generator set side panels.
Change 1