TM 9-6115-647-14&P
5-4
Cable Repair. (See figure 5-4 ) The only cable on the power unit that is repairable is the P4, P7 low fuel
cable. Repair as follows:
a.
Disassembly.
(1)
Loosen screws (1, figure 5-4) to release cable clamps (2) on each backshell (3).
(2)
Unscrew one connector (4) and pull out until rear of connector is accessible.
(3)
Unsolder cable wires from connector pins (Refer to TB SIG 222 and TM 55-1500-323-25 for
soldering procedures )
(4)
Repeat steps (2) and (3) for second connector (4)
(5)
Pull cable (5) out of backshells (3)
(6)
Remove sleeving (6) from cable (5)
b.
Assembly.
(1)
Install sleeving (6) on cable (5).
(2)
Insert one end of cable (5) into clamp end of one backshell (3) and pull ends through and out
connector end
NOTE
If one wire In cable was cut or broken during disassembly, all wires must
be cut to the same length.
(3)
Solder cable wires to connector pins (Refer to figure 4-3 when making electrical connections
Refer to TB SIG 222 and TM 55-1500-323-25 for soldering procedures.)
(4)
Retract cable (5) into backshell (3) and screw connector (4) into backshell.
(5)
Tighten screws (1) and backshell cable clamp (2).
(6)
Repeat steps (2) through (5) for opposite end of cable assembly.
5-8