(9) Remove two hose clamps (16) from each of four generator set fuel tank vent lines (17) and retain for
installation on new generator set (6).
(10) Close generator set side panels.
(11) Remove eight screws (18) and eight lockwashers (19) securing generator set (6) to trailer.
WARNING
When lifting generator set, use equipment with a minimum lifting capacity of 5000
lb. Do not stand under generator set while it is being lifted. Do not permit
generator set to swing. Failure to observe these precautions can cause injury to
personnel or damage to equipment.
(12) Attach lifting equipment (20) with a minimum lifting capacity of 5000 lb to both lifting eyes (21) on
top edge of generator set (6) . Insert a rope (22) through each of four tiedown rings (23) on
generator
set.
(13) With one person at each rope to steady and guide generator set (6), lift generator set off trailer.
b.
Installation.
WARNING
When lifting generator set, use equipment with a minimum lifting capacity of 5000
lb. Do not stand under generator set while it is being lifted. Do not permit
generator set to swing. Failure to observe these precautions can cause injury to
personnel or damage to equipment.
(1) Attach lifting equipment (20) with a minimum lifting capacity of 5000 lb to both lifting eyes (21) on top
edge of generator set (6) . Insert a rope (22) through each of four tiedown rings (23) on generator set.
(2) With one person at each rope to steady and guide generator set (6), lift generator set and carefully
lower it onto trailer.
(3) Insert eight screws (18), with one lockwasher (19) each, through generator set skids into threaded
inserts in generator supports (24).
(4) Open generator set side panels.
(5) Remove sleeve plate assembly (14) from curbside front of generator set (6) and store hardware in
generator set storage compartment. Using four screws (12), four lockwashers (13) and four
spacers
(15) retained during generator set removal, mount sleeve plate assembly in its storage position
on
roadside front of generator set, as shown in figure 5-1.
(6) Install adapter plate assembly (3) on curbside front of generator set (6) with six screws (10) and six
lockwashers (11).