TM 9-6115-647-14&P
(3)
Repeat step (2) for each remaining wire in harness. Refer to figure 4-9 for correct origin and
destination of each wire.
(4)
If an open is detected in wiring harness, replace wiring harness (paragraph 4-24) or notify
higher level of maintenance for repair.
d.
P8 Wring Harness Testing. Wiring harness P8 runs from connector J9 on contactor K2 to terminal
board TB1.
(1)
Set multimeter controls for continuity testing.
(2)
Touch one multimeter test probe to connector P8 contact A and touch remaining test probe to
TB1 contact 13. Multimeter must indicate continuity. If it doesn't, there is an open in connector
or wire.
(3)
Repeat step (2) for each remaining wire in harness. Refer to figure 4-9 for correct ongoing
and destination of each wire.
(4)
If an open is detected in wiring harness, replace wiring harness (paragraph 4-24) or notify
higher level of maintenance for repair.
e.
P9 Wiring Harness Testing. Wiring harness P9 runs from connector J8 on contactor K1 to terminal
board TB1.
(1)
Set multimeter controls for continuity testing.
(2)
Touch one multimeter test probe to connector P9 contact A and touch remaining test probe to
TB1 contact 12. Multimeter must indicate continuity. If it doesn't, there is an open in
connector or wire.
(3)
Repeat step (2) for each remaining wire in harness. Refer to figure 4-9 for correct ongoing and
destination of each wire.
(4)
If an open is detected in wiring harness, replace wiring harness (paragraph 4-24) or notify
higher level of maintenance for repair.
f.
Control Relay/Diodes Wiring Harness Testing. The control relay/diodes wiring harness runs from
terminal TB1 to relay K3 and diodes CR1 through CR4.
(1)
Set multimeter controls for continuity testing.
(2)
Touch one multimeter test probe to XK3 contact 2 and touch remaining test probe to TB1
contact 5. Multimeter must indicate continuity. If it doesn't, there is an open in wire, TB1 or
XK3.
(3)
Repeat step (2) for each remaining wire in harness. Refer to figure 4-9 for correct ongoing and
destination of each wire.
(4)
If an open is detected in wiring harness, replace wiring harness (paragraph 4-24) or notify
higher level of maintenance for repair.
4-31