TM 9-6115-647-14&P
(9)
Disconnect EMI sealing grip body (18) from interconnector (14) Remove body (18), nylon
bushing (19), interconnector (14), rubber bushing (17), gland washer (16), cable grip (15) and
gland nut (13) from cable.
(10)
Remove three screws (20), three flat washers (21), three self-locking nuts (22) and three loop
clamps (23) mounting cable to trailer frame. Remove loop clamps from cable.
b.
Installation .
(1)
Install loop clamps (23) on cable and fasten each clamp to trailer frame with one screw (20),
one flat washer (21) and one self-locking nut (22).
(2)
Slide gland nut (13) onto cable.
(3)
Collapse cable grip (15) and slide cable grip onto cable. Stretch cable grip so that fitting is
about two inches from end of cable outer jacket, and mesh is taut.
(4)
Slide gland washer (16), rubber bushing (17) and interconnector (14) onto cable.
(5)
Slide gland nut (13) over cable grip fitting, and connect interconnector (14) to gland nut (13).
(6)
Slide nylon bushing (19) over cable and into interconnector (14).
(7)
Roll back cable shielding over beveled edge of nylon bushing (19).
(8)
Slide sealing grip body (18) over cable and connect to interconnector (14).
(9)
Slide EMI gasket (12) and one locknut (10) onto cable. Feed wires through opening in PDU
housing (11) and secure with locknut (10).
(10)
Connect cable wires to terminal board TB1 (4), ground stud (5) and K1 contactor (9). Replace
contactor cover (8). Refer to figure 4-7 for correct termination of each wire.
(11)
Close and secure cover (3).
(12)
Connect P3 connector (1) to J3 connector on adapter plate assembly (2).
4-28