TM 9-6115-647-14&P
4-18.
Adapter Plate Assembly Replacement. (See figure 4-4).
a.
Removal.
(1)
Open side panels on generator set (1, figure 4-4).
(2)
Unplug P3 power/control cable (2) and P4, P7 low fuel cable (3) from adapter plate assembly
(4).
NOTE
P12, J11 wiring harness is not a component of adapter plate assembly and,
therefore, must not be removed with the adapter plate assembly
(3)
Disconnect ground cable from adapter plate assembly GROUND (10)
(4)
Tag and disconnect P12, J11 wiring harness (5) from terminal board TB2 (6) on adapter plate
assembly (4).
(5)
Tag and disconnect J3 wiring harness (7) from generator set load terminals.
(6)
Remove six screws (8) and six lockwashers (9) and remove adapter plate assembly (4) from
generator set (1).
b.
Installation .
(1)
Position adapter plate assembly (4) on generator set (1) and fasten with six screws (8) and six
lockwashers (9).
(2)
Connect J3 wiring harness (7) to generator set load terminals. Refer to figure 4-3 for wiring
information.
(3)
Connect P12, J11 wiring harness (5) to terminal board TB2 (6). Refer to figure 4-3 for wiring
information.
(4)
Connect P3 power/control cable (2) and P4, P7 low fuel cable (3) to adapter plate assembly
(4). Connect ground cable to adapter plate GROUND (10).
(5)
Close side panels on generator set (1).
Change 1
4-23