ARMY TM 9-6115-645-24
AIR FORCE TO 35C2-3-444-12
MARlNE CORPS TM 09244A/09245A-24/2
CATHODE
SIDE
ANODE
SIDE
FIGURE 2-18. Diode Identification
2-66.3 Removal.
a.
Shut down generator set.
b. Open battery access door and disconnect negative battery cable.
c.
Remove control box top panel, paragraph 215.1.
d. Tag and disconnect resistor-diode assembly (71, FIGURE 214) electrical leads.
e.
Remove screws (70) and resistor-diode assembly (71 ).
2-66.4 Repair.
Repair resistor-diode assembly (71, FIGURE 2-1 4) by replacing resistors (72) and diodes (73).
2--86.5 Installation.
a.
Install resistor-diode assembly (71, FIGURE 2-1 4) and secure with screws (70).
b. Connect electrical leads and remove tags.
c.
Install control box top panel, paragraph 2-15.4.
d. Connect negative battery cable. Close battery access door.
2-67 CONTROL PANEL.
2-67.1 Removal.
a.
Shut down generator set.
b. Open battery access door and disconnect negative battery cable.
c.
Remove press to test lights from control panel (do not unsolder wires), paragraph 221 .3.
d. Remove VOLTAGE adjust potentiometer from control panel (do not remove wires), paragraph 234.2.
e.
Remove FREQUENCY adjust potentiometer from control panel (do not remove wires), paragraph 235.2.
f.
Tag and disconnect all electrical leads to remaining indicators and switches on control panel(10,FIGURE2-19).
g.
Remove screw (1), nut (2), and strap (3).
h. Remove bolts (4) and (6), nuts (5) and (7), bracket (9), clamp (8), and control panel (10) from control box assembly.
i.
Remove bolts (11 ), nuts (12), and hinge(13) from control box assembly.
2-67.2 Inspection.
Inspect control panel (10, FIGURE 2-19) for dents, cracks, loose paint, and corrosion.
2-97