ARMY TM 9-6115-644-24
AIR FORCE TO 36C2-3-446-12
MARINE CORPS TM 09249A/09246A-24/2
n.
Install output box access door, paragraph 2-14-4.
o.
Install generator housing rear panel, paragraph 2-18-4.
p.
Install control box assembly, paragraph 2-19-4.
q.
Connect negative battery cable and dose battery access door.
Section V. MAINTENANCE OF ENGINE ACCESSORIES
4-15 GOVERNOR ACTUATOR.
4-15-1 Testing.
a.
Shut down generator set.
b.
Open battery access door and disconnect negative battery cable.
c.
Open left side engine access doors and disconnect connector (1, FIGURE 4-8) from engine electrical harness.
d.
Connect 5 ohm, 25 watt resistor in series with pin 2 of connector (1) and ground.
e.
Connect jumper wire from pin 1 of connector (1) to battery positive terminal (24 VDC).
f.
Connect negative battery cable. Governor actuator (11) shaft should extend to full fuel position.
g.
Disconnect negative battery cable. Governor actuator shaft should retract to no fuel position.
h.
Replace governor actuator if it does not function as above.
i.
Remove resistor and jumper wire from connector (1), ground, and battery.
j.
Connect connector (1) to engine electrical harness and close left side engine access doors.
k.
Connect negative battery cable and dose battery access door.
4-15-2 Removal.
a.
Shut down generator set.
b.
Open battery access door and disconnect negative battery cable.
c.
Open left side engine access doors and remove DEAD CRANK switch, paragraph 2-111-2.
d.
Tag and disconnect connector (1, FIGURE 4-8) from electrical harness.
e.
Remove nuts (2) and (3) bolt (4) and rod assembly (5) from fuel injection pump lever and clevis (7).
NOTE
Count number of turns required to remove clevis (7) for initial adjustment during
installation.
f.
Loosen nut (6) and unscrew clevis (7) from governor actuator shaft.
4-27