ARMY TM 9-6115-644-24
AIR FORCE TO 35C2-3-446-12
MARINE CORPS TM 09249A/09246A-24/2
g.
Remove nuts (8, 28) lockwashers (9) bolts (10), and governor actuator (11) from mounting bracket (18).
h.
Remove nut (12), bolt (13), and damp (14) securing electrical wiring to mounting bracket (18).
i.
Remove nuts (15), lockwashers (16,) washers (17), and mounting bracket (18) from front cover mounting bolts.
NOTE
Count number of turns required to separate rod ends for initial adjustment during
installation.
j.
If necessary, disassemble rod assembly (5) by loosening nuts (19) and (20) and unscrewing rod ends (21) and
(22) from rod (23).
k.
If necessary, remove nut (24) and bolt (25) from rod end (22).
I.
If necessary, drill out rivets (26) and remove identification plate (27) from bracket (18).
4-15-3 Installation.
a.
b.
C.
d.
e.
f.
g.
If disassembled, screw rod ends (21 and 22, FlGURE 4-8) onto rod (23) the same number of turns noted on
disassembly, and tighten nuts (19) and (20) finger tight only.
If removed, install bolt (25) and nut (24) into rod end (22).
If removed, install identification plate (27) on bracket (18) with rivets (26).
Install mounting bracket (18) on front cover mounting bolts with washers (17) lockwashers (16) and nuts (15).
Secure electrical wiring to mounting bracket (18) with clamp (14), bolt (13). and nut (12).
Install governor actuator (11) on mounting bracket (18) with bolts (10), lockwashers (9) and nuts (8, 28).
Screw clevis (7) on governor actuator shaft the same number of turns noted on disassembly, and tighten nut
(6) finger tight only.
h.
Install rod assembly (5) on injection pump lever and clevis (7) with bolt (4) and nuts (2) and (3).
i.
Install DEAD CRANK switch, paragraph 2-111-3.
j
Connect connector (1) to engine harness and remove tag.
k
Connect negative battery cable and close battery access door.
l.
Adjust governor actuator in accordance with paragraph 4-15-4 .
4-15-4 Adjustment.
a.
Tag and disconnect connector (1, FIGURE 4-7) from engine harness.
b.
Remove nut(2) and disconnect rod assembly (5).
c.
Manually move fuel injection pump lever to full fuel position.
d.
Start generator set while holding fuel injection pump lever in position.
e.
Slowly move fuel injection pump lever toward no fuel position until generator set shuts down.
Change 1 4-29