Remove bolts (29), nuts (30), lockwashers (31), flatwashers (32), and wire holder (33) from mount (36).
Remove bolts (34), lockwashers (35), clamp (37), and mount (36) from engine.
Installation
Install mount (36, FIGURE 2-24) and clamp (37) on engine with bolts (34) and lockwashers (35).
Install wire holder (33) on mount (36) with bolts (29), flatwashers (32), lockwashers (31), and nuts (30).
Install coolant overflow bottle (28) in holder (33) and connect hoses (25) and (27) with clamps (24) and (26).
Fill overflow bottle (28) with coolant to the COLD level. Refer to TABLE 2-1 for proper coolant.
Start generator set, check for leaks, and run until normal operating temperature is reached.
Add coolant to HOT level of overflow bottle (28) and dose right side engine access doors.
S e c t i o n X I I I . M A I N T E N A N C E O F F U E L S Y S T E M
2-86 LOW PRESSURE FUEL LINES AND FITTINGS.
2-86-1
a.
b.
c.
d.
e.
f.
2-86-2
a.
b.
c.
d.
e.
Removal.
Shut down generator set.
Open battery access door and disconnect negative battery cable.
Identify fuel line or fitting that is damaged or leaking and must be removed as shown in FIGURE 2-26.
Disconnect fuel line at both ends and remove any clamps.
Remove fuel line or fitting from generator set.
Cover or cap all openings.
Installation.
Remove any caps and position fuel line or fitting in generator set.
Install any clamps as removed and connect fuel line at both ends.
Connect negative battery cable and dose battery access door.
Start generator set and check for fuel leaks.
Shut down generator set and dose all access doors.
2-87 AUXlLlARY FUEL PUMP
2-87-1 Inspection.
a.
Shut down generator set.
b.
Inspect auxiliary fuel pump (8, FlGURE 2-26) for leaks, cracks, missing hardware, loose connections, and other
damage.
2-87-2 Testing
a.
Shut down generator set.