ARMY TM 9-6115-643-24
AIR FORCE TO 35C2-3-445-22
NOTES:
1.
Dimensions shown are in inches.
2.
Refer to TM 9-6115-643-24P for materials required.
PROCEDURES:
1.
2.
3.
4.
5.
6.
Cut wire (1) to length indicated.
Strip 0.75 inch of insulation sleeving from each end of wire (1).
Mark insulation sleeving (2) with wire number 165AO", position on center of wire and shrink to fit.
Mark insulation sleeving (4) with POSITIVE" and slide over each end of wire (1).
Crimp terminal (3) on each end of wire (1).
Position insulation sleeving (4) as shown and shrink to fit.
FIGURE D-5. Cable Assembly, Battery (P/N: 88-22310)
D-5