ARMY TM 9-6115-643-24
AIR FORCE TO 35C2-3-445-22
NOTES:
1.
Dimensions shown are in inches.
2.
Refer to TM 9-6115-643-24P for materials required.
PROCEDURES:
1.
Cut wire (1) to length indicated.
2.
Strip 0.75 inch of insulation from each end of wire (1).
3.
Position insulation sleeving (2) on center of wire, mark with wire number 100BO" and shrink to fit.
4.
Crimp terminal (3) on one end of wire (1) and terminal (4) on other end.
FIGURE D-4. Cable Assembly, Battery (P/N: 88-22309)
D-4