NOTES:
1.
Dimensions shown are in inches.
2.
Refer to TM 9-6115-643-24P for terminals required.
PROCEDURES:
1.
Cut each lead of capacitor (1) to obtain dimension shown with terminals (2) installed.
2.
Strip 0.25 inch from each lead of capacitor (1).
3.
Crimp and solder terminals (2) on end of each lead.
FIGURE D-7. Capacitor Assembly, EMI (P/N: 88-22758)
D-7