ARMY TM 9-6115-643-24
AIR FORCE TO 35C2-3-445-22
NOTES:
1.
Dimensions shown are in inches.
2.
Refer to TM 9-6115-643-24P for materials required.
PROCEDURES:
1.
2.
3.
4.
5.
6.
Cut wire (1) to length indicated.
Strip 0.75 inch of insulation from each end of wire (1).
Position insulation sleeving (2) on center of wire, mark with wire number 100AO" and shrink to fit.
Mark insulation sleeving (4) with NEGATIVE" and slide over one end of wire (1).
Crimp terminal (3) on each end of wire (1).
Position insulation sleeving (4) as shown and shrink to fit.
FIGURE D-2. Cable Assembly, Battery (P/N: 88-22123)
D-2