ARMY TM 9-6115-643-10
AIR FORCE TO 35C2-3-445-21
2-5 PMCS PROCEDURES - Continued.
TABLE 2-3. Operator Preventive Maintenance Checks and Services
Location
Procedure
Not Fully Mission
Item to be
Interval
Item
Capable if:
Check/Service
Number
Generator Set
Exterior
NOTE
If The equipment must be kept in
continuous operation, check and
service only those items that can be
checked and serviced without
disrupting operations. Complete all
checks and services when
equipment is shut down.
22
Housing
Check door panels, hinges, and
During
Cannot secure
latches for damage, loose, or
door.
corroded items.
Engine
Assembly
With any access door open while the
noise level may cause hearing
damage. To avoid hearing damage,
hearing protection should be worn.
WARNING
are highly explosive. DO NOT smoke
or use open flame when performing
maintenance. Flames and explosion
can occur resulting in severe injury
or death.
23
Inspect for loose, damaged, or
Any loose, dam-
During
Engine
aged, or missing
missing hardware.
Assembly
hardware.
24
Any fuel leaks,
Inspect for leaks, damage, loose, or
Fuel System
During
damage, loose or
missing hardware.
missing parts.
25
Lubrication
Class III leaks,
Inspect for leaks, damage, loose or
During
System
missing parts.
damage, loose or
missing parts.
Oil level is low.
Inspect oil level.
Oil shows signs of
2-13