TM 9-6115-643-10 ARMY
TO 35C2-3-445-21 AIR FORCE
2-5 PMCS PROCEDURES - Continued.
TABLE 2-3. Operator Preventive Maintenance Checks and Services
Location
Not Fully Mission
Procedure
Item to be
Interval
Item
Capable if:
Check/Service
Number
Cooling
System
Damaged or loose.
During
Inspect for obstruction, damage, or
26
Cooling Fan
looseness.
Unusual noise
Inspect for unusual noise in fan area.
from area.
Class III leaks or
Inspect for proper mounting, leaks,
During
27
Overflow
missing hardware.
or missing hardware.
Bottle
Grounding
Rod Assembly
Damaged, cor-
Inspect for damage, corrosion, and
28
Ground Rod
During
roded, or loose
loose connections.
Cable and
connections.
Connections
Control Box
Assembly
WARNING
High voltage is produced when this
Personal injury or death due to
electrocution could result.
Indicators are
29
Inspect indicators are operating
Controls and
During
not operating
properly.
Indicators
properly.
Exterior
NOTE
If The equipment must be kept in
service continuous operation,
check and only those items that can
be checked and serviced without
disrupting operations. Complete
all checks and services when
equipment is shut down.
30
Housing
Check door panels, hinges, and
After
latches for damage, loose, or
Cannot secure
corroded items.
door.
31
Identification
Check to ensure identification plates
After
are secure
Plates
32
Skid base is
Inspect skid base for cracks and/or
Skid Base
After
cracked or shows
corrosion.
I
signs of structural
damage.
2-14