TM 9-6115-643-10 ARMY
TO 35C2-3-445-21 AIR FORCE
25 PMCS PROCEDURES - Continued.
Operator Preventive Maintenance Checks and Services - Continued
TABLE 2-3.
Location
Procedure
Not Fully Mission
Item to be
Item
Interval
Capable if:
Check/Service
Number
Electrical
System
Battery Acid can cause burns to
unprotected skin.
Batteries give off a flammable gas.
DO NOT smoke or use open flame
when performing maintenance.
Flames and explosion could result in
severe personal injury or death.
electrical components even with
grounding self when in contact with
electrical components. Personal
injury or death due to electrocution
could result.
Electrolyte is be-
Batteries
Inspect electrolyte level.
Before
17
low battery plates.
Battery Cables Inspect for corrosion, damage, loose
Damaged, loose, or
Before
18
connections, or missing parts.
missing parts.
Inspect cables for damage or loose
Damaged, loose, or
Before
19
Output Box
Assembly
connections.
missing parts.
Inspect output terminals for damage
Damaged or mis-
or missing hardware.
sing hardware.
Control Box
Assembly
Controls and
Inspect for damage or missing parts.
Damaged or mis-
Before
20
sing parts.
Indicators
High voltage is produced when this
generator set is in operation.
Personal injury or death due to
electrocution could result.
Before
21
Inspect for damage and looseness.
Damaged or loose.
Control Box
Harness