NOTES:
1. Dimensions shown are in inches.
2. Refer to TM 9-6115-642-24P for materials required.
PROCEDURES:
1. Cut wire (1) to length indioated.
2. Strip 0.75 inch of insulation from each end of wire (1).
3. Mark insulation sleeving (2) with wire number 10962, position on center of wire and shrink to fit.
4. Mark insulation sleeving (3) with NEGATIVE and slide over each end of wire (1).
5. Crimp terminal (4) on one end of wire (1) and terminal (5) on other end as shown.
6. Position insulation sleeving (3) as shown and shrink to fit.
FIGURE D-5. Cable Assembly, Battery (P/N: 88-20316)