ARMY TM 9-6115-642-24
AIR FORCE TO 35C2-3-455-12
MARINE CORPS TM 09247A/09248A-24/2
D-2
ILLUSTRATIONS.
NOTES:
1. Dimensions shown are in inches.
2. Refer to TM 9-6115-642-24P for materials required.
PROCEDURES:
1.
2.
3.
4.
5.
6.
7.
Cut wire (1) to length indicated.
Strip 0.75 inch of insulation from each end of wire (1).
Mark insulation sleeving (2) with wire number100A2, position on center of wire (1) and shrink to fit.
Mark insulation sleeving (3) with NEGATIVE and slide over end of wire (1).
Crimp terminal (4) on end of wire (1) without insulation sleeving (3).
Crimp and solder terminal (5) on end of wire (1) with bolt orientation as shown, and battery post hole tapering open to far
side.
Position insulation sleeving (3) as shown and shrink to fit.
FIGURE D-1. Cable Assembly, Battery (P/N: 88-20312)
D-2