NOTES:
1. Dimensions shown are in inches.
2. Refer to TM 9-6115-642-24P for materials required.
PROCEDURES:
1. Cut wire (1) to length indicated.
2. Strip 0.75 inch of insulation from each end of wire (1).
3. Position insulation sleeving (2) on center of wire, mark with wire number 100B2 and shrink to fit.
4. Crimp terminal (3) on one end of wire (1).
5. Crimp terminal (4) on other end of wire (1).
FIGURE D-2. Cable Assembly, Battery (P/N: 88-20313)