ARMY TM 9-6115-642-24
AIR FORCE TO 35C2-3-455-12
MARINE CORPS TM 09247A/09248A-24/2
NOTES:
1. Dimensions shown are in inches.
2. Refer to TM 9-6115-642-24P for materials required.
PROCEDURES:
1. Cut wire (1) to length indicated.
2. Strip 0.75 inch of insulation sleeving from each end of wire (1).
3. Mark insulation sleeving (2) with wire number 109A2, position on center of wire and shrink to fit.
4. Mark insulation sleeving (3) with POSITIVE and slide over each end of wire (1).
5. Crimp and solder terminal (4) on one end of wire (1) with bolt orientation as shown and battery post hole tapering open
to far side.
6. Crimp terminal (5) on other end of wire (1) as shown.
7. Position insulation sleeving (3) as shown and shrink to fit.
FIGURE D-4. Cable Assembly, Battery (PIN: 88-20315)
D-5