TM 5-6115-640-14&P
NOTE
When generator set is run on auxiliary fuel, as described above, fuel is first pumped into
generator set fuel tank by auxiliary fuel pump. Fuel is then fed to generator set engine from fuel
tank.
Figure 4-2. External Fuel Line Connection.
4-3. DISMANTLING FOR MOVEMENT.
Because the power plants are designed to be mobile, a minimum amount of effort
is required to relocate at a new worksite. Procedures are as follows:
a.
Disconnect power plants from system or equipment being powered.
b.
Disconnect ground cables from source of ground and from power plants' GROUND TERMINAL studs. Roll up
cable and store in accessory box for the AN/MJQ-33 or on rack assembly of AN//JQ-32.
c.
Using slide hammer, remove ground rods. Disassemble, clean, and stow ground rods in accessory box for the
AN/MJQ-33 or on rack assembly for the AN/MJQ-32.
d.
Disconnect power plants from external fuel source, if applicable.
e.
Stow any remaining authorized equipment for the AN/KIQ-33 in accessory box.
4-8