TM 9-6150-228-13&P
4.21 CABLE ASSEMBLIES.
This task covers: Testing
INITIAL SETUP
Tools
General Safety Instructions
Multimeter, Digital (Item 1, Appendix B).
Personnel Required
WARNING
High voltage is present in this equipment
One
during operation. Do not attempt making
any repairs without first shutting down all
input power from the power distribution
panel. Failure to observe this warning
Equipment Conditions
could result in serious injury or death.
Reference
Para 2.5 Equipment shut down.
Para 4.14 Sub panel removed.
NOTE
Both internal and external cables associated with the power distribution panel are tested using a
multimeter to verify continuity
TESTING
a. Internal Cable Assembly.
(1) Preset multimeter (1, Figure 4-14) to perform continuity testing.
(2) Touch probes (2) of multimeter to each end of cable (3), refer to power distribution panel wiring diagram (FO-1)
and Table 4-4. Multimeter should indicate continuity.
Figure 4-14. Internal Cable Assembly.
4-40