5. Tag and disconnect engine harness connector ENG-P12 from the turbo outlet pressure sensor.
6. Remove the turbo outlet pressure sensor (Figure 1, Sheet 1, Item 3) by unscrewing the sensor.
7. Tag and disconnect ECM to EMCP harness connector ENG-P14 from the magnetic speed pickup sensor.
8. Loosen locknut (Figure 1, Sheet 1, Item 5) and remove magnetic speed pickup (Figure 1, Sheet 1, Item 4) by
loosening the top nut and then unscrewing the sensor.