ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
5
4
4
5
1
2
3
1
2
7.50
6.50
[190.50]
[165.10]
TERMINATION (MEP-531A)
TERMINATION (MEP-501A)
WIRE
WIRE
BULK
REF
FROM
TO
FROM
TO
NO.
NO.
1
L4 (Y)
TB1-4
L4 (YEL)
TB1-5
M16878/3BJE-9
2
L4 (R)
TB1-2
L4 (RED)
TB1-3
M16878/3BJE-9
NOTES:
PROCEDURES:
1. Dimensions are shown in inches and
1. Cut each wire (3) to length indicated, then strip
dimensions in [ ] are in millimeters.
0.50 [13] from ends of each wire.
2. Attach wires (3) to solenoid (1) leads with
required.
splices (2).
3. Slide insulation sleeving (5) over wires (3).
4. Crimp terminal lug (4) on one end of each wire.
Install insulation sleeving (5) over terminal lugs
(4) and heat shrink to a firm fit.
5. Mark the appropriate wire number which will
consist of the `FROM' termination, a double-
headed arrow (↔), and the `TO' termination.