ARMY TM 9-6115-673-13&P
AIR FORCE TO 35C2-3-512-1
1
SEE PROCEDURES 3 AND 4
4
5
3
2
1
2
2
5
24.00
.50
[12.7]
[609.6]
TERMINATION
WIRE
WIRE
REF
BULK
NO.
NO.
FROM
TO
1
R2
TB1-12
M16878/3BJE-9
2
R2
TB1-11
M16878/3BJE-9
NOTES:
PROCEDURES:
1. Dimensions are shown in inches and
1. Cut each wire (3) to length indicated then strip
dimensions in [ ] are in millimeters.
0.50 [13] from ends of each wire.
2. Solder wires (3) to terminals on potentiometer
for materials required.
(1).
3. Install 0.25 to 0.75 [6.4 to19.1] of insulation
sleeving (2) over soldered terminals on
potentiometer (1) and heat shrink insulation
to a firm fit.
4. Slide insulation sleeving (5) over wires (3).
Crimp terminal lug (4) on end of wires (3).
Install insulation sleeving (5) over terminal lugs
(4) and heat shrink to a firm fit.
5. Mark the appropriate wire number which will
consist of the `FROM' termination, a double
headed arrow (↔), and the `TO' termination.