ARMY TM 9-6115-672-14
AIR FORCE TO 35C2-3-444-32
MARINE CORPS TM 09244A/09245A-14
5-38
FIGURE 5-6. TESTING DROOP CURRENT TRANSFORMER
(7)
Remove droop current transformer from test circuit.
(8)
Install droop current transformer, refer to paragraph 5.8.5.c.
c. Installation.
(1)
Install droop current transformer (7, Figure 5-4), screws (6), and locknuts (5) on rear panel (33).
(2)
Connect droop current transformer (7) electrical leads to terminal board (35). Remove tags.
(3)
Install main generator cables on droop current transformer (7) the same number of wraps
recorded during removal.
(4)
Connect main generator cables T2 and T8 to voltage reconnection board (34). Remove tags.
(5)
Close output box and engine compartment access doors.
(6)
Connect negative battery cable to battery, and close BATTERY ACCESS door.
5.8.6
Power Potential Transformer T1.
a. Removal.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.
(3)
Remove DCS control box assembly, paragraph 4.8.1.
(4)
Remove output box top panel, paragraph 5.8.1.
(5)
Tag and disconnect electrical leads from power potential transformer (10, Figure 5-4).
(6)
Remove locknuts (8), screws (9), and power potential transformer (10) from rear panel (33).
b. Installation.
(1)
Install power potential transformer (10, Figure 5-4), screws (9), and locknuts (8) on rear panel
(31).
(2)