c. Replacement.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.
(3)
Remove fan guard from left side of generator set. Refer to paragraph 4.10.3.
(4)
Remove dead crank switch plate (10, Figure 4-29).
(5)
Disconnect output box wiring harness from electrical connector (1, Figure 5-7).
(6)
Loosen coupling nut (2), and remove fuel line (3) and seal (4) from elbow (5).
(7)
Remove elbow (5), seal (6), adapter (7), seal (8), and adapter (9) from electric actuator (11).
NOTE
One cap screw is longer than the others. Note position of cap screws for
installation later.
(8)
Remove cap screws (10), electric actuator (11), and gasket (12) from engine.
(9)
Position gasket (12) and electric actuator (11) on engine. Secure with cap screws (10) as noted
in step (6).
(10) Install adapter (9), seal (8), adapter (7), seal (6), and elbow (5) on electric actuator (11).
(11) Position seal (4) and fuel line (3) on elbow (5). Tighten coupling nut (2).
(12) Connect output box wiring harness to electrical connector (1).
(13) Install fan guard from left side of generator set. Refer to paragraph 4.10.3.
(14) Install dead crank switch plate (10, Figure 4-29).
(15) Connect negative battery cable to battery, and close BATTERY ACCESS door.
5.10
MAINTENANCE OF GENERATOR ASSEMBLY.
__________
WARNING
When disconnecting or removing batteries, disconnect the negative lead
that connects directly to the grounding stud first. Disconnect the negative
end of the interconnection cable next. When installing batteries, reverse the
connection sequence. Failure to comply can cause serious personal injury.