ARMY TM 9-6115-672-14
AIR FORCE TO 35C2-3-444-32
MARINE CORPS TM 09244A/09245A-14
5-22
FIGURE 5-1. ENGINE AND GENERATOR ASSEMBLY (SHEET 2 OF 2)
5.5
MAINTENANCE OF DCS CONTROL BOX ASSEMBLY.
__________
WARNING
When disconnecting or removing batteries, disconnect the negative lead
that connects directly to the grounding stud first. Disconnect the negative
end of the interconnection cable next. When installing batteries, reverse the
connection sequence. Failure to comply can cause serious personal injury.
5.5.1
DCS Control Box Wiring Harness.
CAUTION
Electronic components containing printed circuit boards are extremely
sensitive to electrostatic discharge (ESD). Wear an ESD wrist strap
connected to ground whenever coming in contact with ESD-sensitive
components. Failure to comply can cause severe damage to equipment.
a. Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Remove DCS control box top panel, paragraph 4.7.2.
(3)
Attach ESD wrist strap and connect to ground.