ARMY TM 9-6115-672-14
AIR FORCE TO 35C2-3-444-32
MARINE CORPS TM 09244A/09245A-14
5-24
Replacement.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.
(3)
Remove DCS control box top panel, paragraph 4.7.2.
(4)
Remove sleeving (14), tag and desolder electrical leads from resistor (10, Figure 4-16). Refer to
Schematic FO-1.
(5)
Remove resistor (10) from auxiliary control bracket (18).
(6)
Install resistor (10) to auxiliary control bracket (18).
(7)
Install sleeving (14) and solder electrical leads to resistor (10). Remove tags.
(8)
Install DCS control box top panel, paragraph 4.7.2.
(9)
Connect negative battery cable to battery, and close BATTERY ACCESS door.
5.5.3
Resistor R2
Replacement.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.
(3)
Remove DCS control box top panel, paragraph 4.7.2.
(4)
Tag and desolder electrical leads from resistor (13, Figure 4-16).
(5)
Remove nuts (11), lockwashers (12), resistor (13), sleeving (14), screws (15), and lockwashers
(16) from auxiliary control bracket (18).
(6)
Install lockwashers (16), screws (15), sleeving (14), resistor (13), lockwashers (12), and nuts
(11) on auxiliary control bracket (18).
(7)
Solder electrical leads to resistor (13). Remove tags.
(8)
Install DCS control box top panel, paragraph 4.7.2.
(9)
Connect negative battery cable to battery, and close BATTERY ACCESS door.
5.6
MAINTENANCE OF COOLING SYSTEM.
5.6.1
Radiator.
Repair radiator in accordance with TM 750-254.