ARMY TM 9-6115-672-14
AIR FORCE TO 35C2-3-444-32
MARINE CORPS TM 09244A/09245A-14
4-195
__________
WARNING
When disconnecting or removing batteries, disconnect the negative lead that
connects directly to the grounding stud first. Disconnect the negative end of
the interconnection cable next. When installing batteries, reverse the
connection sequence. Failure to comply can cause serious personal injury.
4.13.1 Oil Pressure Sender MT7.
a. Testing.
(1)
Start generator set, paragraph 2.11.1.
(2)
Open left side engine compartment access doors (Figure 1-3).
(3)
Set multimeter to VDC. Place positive lead of multimeter on the black wire lead of the oil pressure
sender connector, and the negative lead to ground. Readings shall be between 1 and 5 VDC.
(4)
Shut down generator set, paragraph 2.11.2.
(5)
If indications are not as above, replace oil pressure sender (1), refer to paragraph 4.13.1. b and d.
b. Removal.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.
(3)
Open left side engine compartment access doors (Figure 1-3).
(4)
Disconnect electrical plug connector from oil pressure sender (1, Figure 4-30).
(5)
Remove oil pressure sender (1) from adapter (10).
c. Service.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Remove oil pressure sender, refer to paragraph 4.13.1.b.
__________
WARNING
Cleaning with compressed air can cause flying particles. When using
compressed air, wear protective glasses and use clean, low pressure air, less
than 30 psi (206.8 kPa). Failure to comply can cause eye injury.