a. Removal.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.
(3)
Open load terminal board access door (Figure 1-2), and disconnect load output cables L1, L2, L3,
and N from load output terminal board.
(4)
Remove rear housing panel. Refer to paragraph 4.7.5.
(5)
Remove locknut (1, Figure 4-29), bolt (2), and lockwashers (3) securing ground strap (20) to skid
base.
(6)
Remove bolts (4), lockwashers (5), and washers (6) securing load output terminal board (11) to
supports (34 and 35).
(7)
Remove locknuts (7), brass washers (8), electrical leads (9), and varistor leads (10) from load
terminals (14). Tag leads.
(8)
Remove terminal load board (11) from generator set.
(9)
Remove jamnuts (12), brass washers (13), and load terminals (14) from load output terminal board
(11).
(10) Remove locknuts (15), washers (16), and bus bar (17) from terminal studs (21 and 26).
(11) Remove locknut (18), lockwasher (19), ground strap (20), and terminal stud (21) from load output
terminal board (11).
(12) Remove locknut (22), washer (23), ground bus bar (24), EMI filter (25), and terminal stud (26) from
load output terminal board (11).
(13) Disconnect varistor leads (10) from varistors (29).
(14) Remove locknuts (27), bolts (28), varistors (29), EMI filters (30), and ground plane bar (31) from
load output terminal board (11).
(15) Remove locknuts (32), bolts (33), and terminal board supports (34 and 35) from generator set.
(16) Remove locknuts (36), bolts (37), cord (38), insulated wrench (39), and bracket (40) from terminal
board support (34).