ARMY TM 9-6115-672-14
AIR FORCE TO 35C2-3-444-32
MARINE CORPS TM 09244A/09245A-14
4-170
(1)
Install mounting bracket (14, Figure 4-25), washers (13), and bolts (12) on engine.
(2)
Install wire holder (11), bolts (9), washers (10), washers (8), lockwashers (7), and nuts (6) on
mounting bracket (14).
(3)
Install overflow bottle (5) in wire holder (11).
(4)
Position hose clamps (1 and 3) and hoses (2 and 4) on overflow bottle (5). Tighten hose clamps.
(5)
Fill overflow bottle (5) with coolant to the COLD level. Refer to Table 3-2 for proper coolant.
(6)
Start generator set, paragraph 2.11.1. Check for leaks, and run until normal operating temperature is
reached.
(7)
Add coolant to HOT level of overflow bottle (5).
(8)
Close engine compartment access doors.
4.11
MAINTENANCE OF FUEL SYSTEM.
__________
WARNING
When disconnecting or removing batteries, disconnect the negative lead that
connects directly to the grounding stud first. Disconnect the negative end of
the interconnection cable next. When installing batteries, reverse the
connection sequence. Failure to comply can cause serious personal injury.
4.11.1 Low Pressure Fuel Lines and Fittings.
a. Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable .
(3)
Open engine compartment access doors (Figures 1-2 and 1-3).
(4)
Inspect fuel lines and fittings for damage or leaking condition. Damaged components must be
replaced. Identify components. Refer to Figure 4-26.
b. Replacement.
(1)
Inspect low pressure lines and fittings. Identify damaged components found during inspection.
Damaged lines and fittings must be replaced. Refer to Figure 4-26.
(2)
Disconnect fuel line at both ends, and remove any clamps.
(3)
Remove fuel line or fitting from generator set.
(4)
Cover or cap all openings.