ARMY TM 9-6115-672-14
AIR FORCE TO 35C2-3-444-32
MARINE CORPS TM 09244A/09245A-14
4-171
(5)
Remove any caps, and position fuel line or fitting in generator set.
(6)
Install any clamps as removed, and connect fuel line at both ends. Tighten clamps.
(7)
Connect negative battery cable to battery, and close BATTERY ACCESS door.
(8)
Start generator set, paragraph 2.11.1. Check for fuel leaks.
(9)
Shut down generator set, paragraph 2.11.2.
(10) Close engine compartment access doors.
4.11.2 Auxiliary Fuel Pump E1.
a. Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open left side engine compartment access doors (Figure 1-3).
(3)
Inspect auxiliary fuel pump (11, Figure 4-26) for leaks, cracks, missing hardware, loose
connections, and other damage.
(4)
Close engine compartment access doors.
b. Testing.
(1)
Shut down generator set, paragraph 2.11.2.
NOTE
Ensure auxiliary fuel supply is no more than 6 feet (1.83 m) below generator set.
(2)
Connect generator set to auxiliary fuel supply.
(3)
Open left side engine compartment access doors (Figure 1-3).
(4)
Disconnect auxiliary fuel pump outlet line (5, Figure 4-26) at fuel tank fitting, and place
disconnected end in measuring container.
(5)
Move generator set ENGINE CONTROL switch to PRIME & RUN AUX FUEL position for one
minute, and return ENGINE CONTROL switch to OFF position.
(6)
Measuring container should collect at least 36 ounces (1.06 liters) of fuel. Properly dispose of fuel.
(7)
Replace auxiliary fuel pump (11) if delivery amount is less than above.
(8)
Connect auxiliary fuel pump outlet line (5) at fuel tank fitting.
(9)
Disconnect generator set from auxiliary fuel supply.
(10) Close engine compartment access doors.