ARMY TM 9-6115-672-14
AIR FORCE TO 35C2-3-444-32
MARINE CORPS TM 09244A/09245A-14
4-164
(14) Install radiator cap (1) on filler neck (2).
(15) Start generator set, paragraph 2.11.1. Allow unit to reach operating temperature, and check for
leaks.
(16) Add coolant/antifreeze to overflow bottle as required.
(17) Close engine compartment access doors.
4.10.8 Fan.
a. Removal.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.
(3)
Open engine compartment access doors (Figures 1-2 and 1-3).
(4)
Remove fan guards, paragraph 4.10.3.
(5)
Remove bolts (16, Figure 4-22), lockwashers (17), and washers (18), and allow shroud (19) to rest
on fan (40).
(6)
Remove bolts (38), lockwashers (39), fan (40), and spacer (41) from engine water pump.
(7)
Remove locknuts (42), screws (43), stiffeners (44), supports (45), and seals (46) from shroud (19).
b. Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Remove fan, step a above.
(3)
Inspect fan (40, Figure 4-22) and blades for cracks, bends, loose rivets, or other damage.
(4)
Inspect spacer (41) for cracks or other damage.
(5)
Inspect seals (46), supports (45), and stiffeners (44) for damage.
NOTE
If installing new seals, screw holes need to be match drilled at assembly.
(6)
Replace damaged parts.
(7)
Install fan, step c below
c. Installation.
(1)
Install seals (46, Figure 4-22), supports (45), stiffeners (44), screws (43), and locknuts (42) on
Shroud (19).
(2)
Position Spacer (41), fan (40), and shroud (19) in generator set.