ARMY TM 9-6115-672-14
AIR FORCE TO 35C2-3-444-32
MARINE CORPS TM 09244A/09245A-14
4-132
(4)
Install DCS control box top panel, paragraph 4.7.2.
b. Testing.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.
(3)
Remove DCS control box top panel, paragraph 4.7.2.
(4)
Set multimeter for ohms, and measure resistance across resistor (41, Figure 4-16). Multimeter
indication should be 40 ohms.
(7)
If any indications are other than above, replace resistor.
(8)
Install DCS control box top panel, paragraph 4.7.2.
(9)
Connect negative battery cable to battery, and close BATTERY ACCESS door.
c. Replacement.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.
(3)
Remove DCS control box top panel, paragraph 4.7.2.
(4)
Tag and desolder electrical leads from resistor (41, Figure 4-16).
(5)
Open output box access door (Figure 1-2) to access nuts (37).
(6)
Remove nuts (37), lockwashers (38), screws (39), lockwashers (40), resistor (41), and sleeving (42)
from floor of DCS control box assembly.
(7)
Install sleeving (42), resistor (41), lockwashers (40), screws (39), lockwashers (38), and nuts (37)
on floor of DCS control box assembly.
(8)
Close output box access door.
(9)
Solder electrical leads on resistor (41). Remove tags.
(10) Install DCS control box top panel, paragraph 4.7.2.
(11) Connect negative battery cable to battery, and close BATTERY ACCESS door.
4.8.37 DCS Control Box Wiring Harness.
CAUTION
Electronic components containing printed circuit boards are extremely
sensitive to electrostatic discharge (ESD). Wear an ESD wrist strap connected
to ground whenever coming in contact with ESD-sensitive components. Failure
to comply can cause severe damage to equipment.