ARMY TM 9-6115-672-14
AIR FORCE TO 35C2-3-444-32
MARINE CORPS TM 09244A/09245A-14
4-63
WARNING
Top housing panels can get very hot. Allow panels to cool down before
performing maintenance. Failure to comply can result in severe burns to
personnel.
(4)
Remove bolts (1, Figure 4-7), lockwashers (2), washers (3), mount (4), and exhaust cover (5) from
top housing panel.
(5)
Remove bolts (6 and 9), lockwashers (7 and 10), washers (8 and 11), and top housing panel (12)
from generator set.
(6)
Disconnect radiator fill hose and overflow hose from radiator fill panel (13), and remove panel (13)
from generator set.
(7)
Remove bolts (14), lockwashers (15), washers (16), and roof stiffener assembly (17, Figure 4-7,
sheet 2) from side panels (33 and 34).
(8)
Remove muffler, paragraph 4.9.1.
(9)
Remove bolts (18), lockwashers 19), washers (20), and air duct channels (21 and 22) from floor
panel (35).
(10) Remove locknuts (23 and 25), bolts (24 and 26), and duct panel (27) from floor panel (35) and side
panels (33 and 34).
(11) Remove locknuts (28) and bolts (29) from side panels (33 and 34).