ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
5-38
FIGURE 5-4. OUTPUT BOX COMPONENTS (SHEET 2 OF 2)
FIGURE 5-5. TESTING CURRENT TRANSFORMER
5.8.5
Droop Current Transformer CT5.
a. Removal.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.
(3)
Open output box and right side engine compartment access doors (Figure 1-2).
(4)
Tag and disconnect main generator cables T2 and T8 from voltage reconnection board (34,
Figure 5-4).
NOTE
Record number and direction of wraps when removing main generator cables
from transformer for installation later.
(5)
Unwrap main generator cables from droop current transformer (7).
(6)
Tag and disconnect droop current transformer (7) electrical leads from terminal board (35).
(7)
Remove locknuts (5), screws (6), and droop current transformer (7) from rear panel (33).