ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
5-36
(5)
Set multimeter for amperes, and connect to secondary terminals A1 and A2. Multimeter
indication must be 0.9 to 1.1 amps.
(6)
Repeat steps (3) through (5) using phase B window and secondary terminals B1 and B2.
(7)
Repeat steps (3) through (5) using phase C window and secondary terminals C1 and C2.
(8)
Replace current transformer if multimeter indication in any phase is other than stated in step (5).
(9)
Remove current transformer from test circuit.
(10) Install current transformer, step 5.8.4.c below.
c. Installation.
(1)
Install current transformer (4, Figure 5-4), washers (3), screws (2), and locknuts (1) on rear
panel (33).
(2)
Install main generator cables on current transformer (4) and droop current transformer (7) the
same number of wraps recorded during removal.
(3)
Connect main generator cables T2 and T8 to voltage reconnection board (34). Remove tags.
(4)
Connect electrical leads to current transformer (4). Remove tags.
(5)
Install output box top panel, paragraph 5.8.1.
(6)
Install DCS control box assembly, paragraph 4.8.1.
(7)
Close output box and engine compartment access doors.
(8)
Connect negative battery cable to battery, and close BATTERY ACCESS door.