ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
4-196
b. Removal.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.
(3)
Open left side engine compartment access doors (Figure 1-3).
(4)
Disconnect electrical plug connector from oil pressure sender (1, Figure 4-30).
(5) Remove oil pressure sender (1) from adapter (10).
c. Service.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Remove oil pressure sender, refer to paragraph 4.13.1.b.
__________
WARNING
Cleaning with compressed air can cause flying particles. When using
compressed air, wear protective glasses and use clean, low pressure air, less
than 30 psi (206.8 kPa). Failure to comply can cause eye injury.
__________
WARNING
Dry cleaning solvent is flammable and toxic to eyes, skin, and respiratory tract.
Skin and eye protection are required when working in contact with dry
cleaning solvent. Avoid repeated or prolonged contact. Work in ventilated
area only. Failure to comply can cause injury or death to personnel.
(3)
Clean oil pressure sender with dry, filtered compressed air, and wipe with a clean, lint-free cloth
(Item 8, Appendix E) lightly moistened with dry cleaning solvent (Item 20, Appendix E).
(4)
Inspect oil pressure sender for cracked casing, stripped or damaged threads, corrosion, or other
damage.
(5)
Replace oil pressure sender if damaged.
(6)
Install oil pressure sender, refer to paragraph 4.13.1.d.
d. Installation.
CAUTION
Use care not to introduce pipe thread sealing compound into the pressure
orifice in the end of the oil pressure sender. Sealing compound in the pressure
orifice can cause the oil pressure sender to malfunction and result in damage to
equipment.