ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
4-102
(4)
Connect power connection to CIM (3). Tighten two screws.
(5)
Install DCS control box top panel, paragraph 4.7.2.
(6)
Connect negative battery cable to battery, and close BATTERY ACCESS door.
4.8.17 Keypad Assembly KP.
CAUTION
Electronic components containing printed circuit boards are extremely
sensitive to electrostatic discharge (ESD). Wear an ESD wrist strap connected
to ground whenever coming in contact with ESD-sensitive components. Failure
to comply can cause severe damage to equipment.
a. Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Remove DCS control box top panel, paragraph 4.7.2.
(3)
Attach ESD wrist strap and connect to ground.
(4)
Inspect keypad assembly (7, Figure 4-14) for sticking or non-responsive buttons, corrosion, loose
and damaged wires or other damage.
(5)
Disconnect ESD wrist strap from ground, and remove wrist strap.
(6)
Install DCS control box top panel, paragraph 4.7.2.
b. Replacement.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.
(3)
Remove DCS control box top panel, paragraph 4.7.2.
(4)
Remove CIM. Refer to Paragraph 4.8.16.
(5)
Attach ESD wrist strap and connect to ground.
CAUTION
Keypad assembly has two electrical connectors. Pins can be damaged or
broken if connectors are pulled from or inserted at an angle. Use care when
connecting or disconnecting wiring harnesses from keypad assembly. Failure
to comply can cause damage to equipment.
NOTE