ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
4-104
(4)
Tag and desolder electrical leads from COMMUNICATION RECEPTACLE (11, Figure 4-14) and
groundwire. Refer to Schematic FO-1.
(5)
Remove locknuts (8), screws (9), cap (10), COMMUNICATION RECEPTACLE (11), and gasket
(12) from DCS control panel frame (4).
(6)
Install gasket (12), COMMUNICATION RECEPTACLE (11), cap (10), screws (9), and locknuts
(8) on DCS control panel frame (4).
(7)
Solder electrical leads to COMMUNICATION RECEPTACLE (11) and connect ground wire.
Refer to Schematic FO-1. Remove tags.
(8)
Install control box top panel, paragraph 4.7.2.
(9)
Connect negative battery cable to battery, and close BATTERY ACCESS door.
4.8.19 PARALLELING RECEPTACLE J2.
a. Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Remove DCS control box top panel, paragraph 4.7.2.
(3)
Inspect PARALLELING RECEPTACLE (16, Figure 4-14) for cracks, corrosion, stripped or
damaged threads, evidence of shorting, and other damage.
(4)
Inspect cap (15) for cracks, corrosion, and broken chain.
(5)
Inspect gasket (17) for tears and deterioration.
(6)
Replace defective parts.
(7)
Install control box top panel, paragraph 4.7.2.
b. Replacement.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable.
(3)
Remove DCS control box top panel, paragraph 4.7.2.
(4)
Tag and disconnect electrical leads from PARALLELING RECEPTACLE (16, Figure 4-14) by
inserting removal tool (Appendix B, Section III) into pins of connector.
(5)
Remove locknuts (13), screws (14), cap (15), PARALLELING RECEPTACLE (16), and gasket
(17) from DCS control panel frame (4).
(6)
Install gasket (17), PARALLELING RECEPTACLE (16), cap (15), screws (14), and locknuts (13)
on DCS control panel frame (4).
(7)
Connect electrical leads to PARALLELING RECEPTACLE (16) using insertion tool (Appendix B,
Section III). Remove tags.