ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
4-60
(7)
Position door (6) on generator set housing, and install hinges (5), bolts (4), washers (3), lockwashers
(2), and nuts (1).
(8)
Close engine compartment access doors.
4.7.2
DCS Control Box Top Panel.
a. Removal.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable. Refer to
paragraphs 4.6.2 and 4.6.3.
(3)
Remove DCS control box door (Figure 1-3). Refer to paragraph 4.7.1.
(4)
Release DCS control panel (4, Figure 1-30) by turning two fasteners, and lower panel slowly.
(5)
Remove bolts (1, Figure 4-6), lockwashers (2), and washers (3) from top panel (4).
NOTE
For ease of access in step 6, remove the CIM. Refer to paragraph 4.8.16.b.
(6)
Remove locknuts (5) and bolts (6) from top panel (4). Close DCS control panel (4, Figure 1-30).
CAUTION
The top panel is attached to the generator set housing with a silicone sealant to
prevent water from entering the control box. Care must be taken not to bend
or scratch the top panel when separating it from the housing. Failure to
comply can cause damage to equipment.
(7)
Carefully separate top panel (4) from generator. Remove control box top panel.
(8)
Remove nuts (7), lockwashers (8), washers (9), and bolts (10) from DCS control box assembly.
(9)
Remove locknuts (12), bolts (13), door ring retainer (14), and door ring (15) from top panel (4).
(10) Remove old sealant from door ring retainer (14).