ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
4-59
b. Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Inspect access doors, hinges, latches, baffles, and storage boxes for loose and missing hardware,
cracks, dents, and loose paint, or corrosion.
(3)
Inspect data plates for readability and loose or missing rivets.
c. Repair.
__________
WARNING
CARC paint is a health hazard. Wear protective eyewear, mask and gloves
when sanding CARC painted surfaces. Failure to comply can cause personal
injury.
(1)
Repair all dents and cracks, and remove loose paint.
(2)
Remove light corrosion with fine grit abrasive paper (Item 16, Appendix E).
(3)
Repaint surfaces in accordance with TM 43-0139.
NOTE
Step (4) applies to all access doors except the load terminal access door.
NOTE
Sealant is applied to all four corners of the output box access door.
(4)
Apply industrial sealant (Item 18, Appendix E) to top two corners of access door.
(5)
Replace damaged or unreadable data plates.
(6)
Replace loose or missing rivets.
d. Installation.
(1)
Position latches (25, Figure 4-5) on door (6) as noted during removal. Secure latches to door with
screws (24), and locknuts (23).
(2)
Install bracket (22), bolts (21), and locknuts (20) on door (6).
(3)
Install bracket (18), holding rod (19), bolts (17), and locknuts (16) on door (6).
(4)
Install fuel system diagram data plate (15) on document box (13) with rivets (14).
(5)
Install document box (13), bolts (12), and locknuts (11) on door (6).
(6)
Install hinges (5), bolts (10), washers (9), lockwashers (8), and nuts (7) on door (6).