ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
4-63
WARNING
Top housing panels can get very hot. Allow panels to cool down before
performing maintenance. Failure to comply can result in severe burns to
personnel.
(4)
Remove bolts (1, Figure 4-7), lockwashers (2), washers (3), mount (4), and exhaust cover (5) from
top housing panel (12).
(5)
Remove bolts (6 and 9), lockwashers (7 and 10), washers (8 and 11), and top housing panel (12)
from generator set.
(6)
Disconnect radiator fill hose and overflow hose from radiator fill panel (13), and remove panel from
generator set.
(7)
Remove bolts (14), lockwashers (15), washers (16), and roof stiffener assembly (17) from side
panels (35 and 36).
(8)
Remove muffler. Refer to paragraph 4.9.1.
(9)
Remove locknuts (18), bolts (19), and air duct channels (20 and 21) from floor panel (37).
(10) Remove locknuts (22 and 24), bolts (23 and 25), and duct panel (26) from floor panel (37) and side
panels (35 and 36).
(11) Remove locknuts (27) and bolts (28) from side panels (35 and 36).
(12) Remove bolts (29), lockwashers (30), and washers (31) from side panels (35 and 36).
(13) Remove bolts (32), lockwashers (33), and washers (34) from front panel (40).
(14) Remove side panels (35 and 36) with floor panel (37) from generator set.
(15) Remove locknuts (38), bolts (39), and front panel (40) from floor panel (37).
(16) Remove locknuts (41), bolts (42), and support (43) from front panel (40).
(17) Remove locknuts (44), bolts (45), and side panels (35 and 36) from floor panel (37).
(18) Remove locknut (46), bolt (47), and bracket (48) from angle (51).
(19) Open output box access door (Figure 1-2), and remove locknuts (49), bolts (50), and angle (51)
from generator set.
(20) Remove clip halves (52) and insulation (53 through 63) from top panel (12).
(21) Remove clip halves (64) and insulation (65 and 66) from side panels (35 and 36).