ARMY TM 9-6115-671-14
AIR FORCE TO 35C2-3-446-32
MARINE CORPS TM 09249A/09246A-14
4-55
(3)
Inspect NATO SLAVE RECEPTACLE (7, Figure 4-4) for loose connections, corrosion, missing
hardware, and other damage.
(4)
Close BATTERY ACCESS door.
b. Removal.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Open BATTERY ACCESS door (Figure 1-2), and disconnect negative battery cable .
(3)
Tag battery and NATO SLAVE RECEPTACLE cables. Remove bolts (1, Figure 4-4), lockwashers
(2), wire (18) and terminals (3) from NATO SLAVE RECEPTACLE (7).
(4)
Remove cover (4) from NATO SLAVE RECEPTACLE (7).
(5)
Remove nuts (5), bolts (6), NATO SLAVE RECEPTACLE (7) and gasket (17) from generator set.
(6)
Remove nut (8), bolt (9), and cover (4) from generator set.
c. Installation.
(1)
Install cap (4, Figure 4-4), with bolt (9), and nut (8) on NATO SLAVE RECEPTACLE (7).
(2)
Position NATO SLAVE RECEPTACLE (7) and gasket (17) in generator set with negative terminal
up.
(3)
Install NATO SLAVE RECEPTACLE (7) and gasket (17), with bolts (6), and nuts (5) on generator
set.
(4)
Install cap (4) on NATO SLAVE RECEPTACLE (7).
(5)
Install terminals (3), wire (18), lockwashers (2), and bolts (1) on NATO SLAVE RECEPTACLE
(7).
(6)
Connect negative battery cable to battery, and close BATTERY ACCESS door.
4.6.5
Keypad Power Supply PS1.
a.
Inspection.
(1)
Shut down generator set, paragraph 2.11.2.
(2)
Remove CIM (see paragraph 4.8.16) from the DCS control box assembly.
(3)
Inspect keypad power supply (44, Figure 4-18) mounting surfaces and terminal screws for damage.
Ensure screws are secure.
(4)
Check for evidence of burned or damaged components on surface of keypad power supply.
(5)