TM 9-6115-670-14&P
5-45
5.15. CURRENT TRANSFORMER.
This task covers: Replace
INITIAL SETUP
Tools
General Mechanic's Tool Kit
(Item 1, Appendix B)
Materials/Parts
Current Transformer
Equipment Conditions
MASTER ON-OFF switch on APU control unit set
to OFF.
Contactor mounting plate removed (para 4.52.).
REPLACE
a. Remove four nuts with captive washers (1, Figure 5-9) and four screws (JTACS and WIN-T), or
slotted hex-head bolts (JTACS and WIN-T) (3) and remove current transformer (2) from
contactor mounting plate (4).
b. Install current transformer (2) to contactor mounting plate (4) and secure with four nuts with
captive washers (1) and bolts (3).
Figure 5-9. Current Transformer
WARNING
Ensure that APU DC power supply is disconnected.
Failure to observe this warning could result in severe
injury or DEATH to personnel.
WARNING
Ensure that the APU is turned off and completely de-
energized before opening generator housing. Failure
to observe this warning could result in severe injury
or DEATH to personnel.