ARMY TM 9-6115-670-14&P
4-75
REPLACE
a. Cut wire ties (if applicable).
b. Remove fuel supply line hose (15).
c. Loosen clamp (6) and remove fuel line (7) from fitting (5) on fuel pump assembly (4).
d. Disconnect P8 connector from J8.
e. Remove screw, lock washer, and flat washer (3) securing fuel pump bracket (1) to generator mount
(8).
f. Loosen screw (14) and nut and lock washer (2), and slide fuel pump (4) out from bracket (1).
g. Slip bracket (1) over fuel pump (4) and tighten screw (14), nut and lock washer (2).
h. Align bracket hole with hole on generator mount (8) and secure with flat and lock washer and screw
(3).
i. Reconnect P-8 to J-8.
j. Install fuel line and tighten clamp (6).
k. Install fuel supply line hose (15) on fuel pump (4).
l. Bleed fuel system (para 4.29.).
m. Reinstall wire ties (if applicable) (16).
WARNING
Ensure that NO IGNITION SOURCE is within 50 feet of
the 10 kW APU. The fuel in this APU is highly flammable.
Do not smoke. Do not splash fuel on hot components.
Failure to heed this warning could result in serious injury
to personnel or DEATH.
WARNING
Avoid fuel contact with skin. Wear protective gloves while
disconnecting fuel lines. Failure to heed this warning
could result in serious injury to personnel or DEATH.
NOTE
When disconnecting fuel lines, use suitable container to
catch fuel leaking from disconnected fuel lines.