ARMY TM 9-6115-670-14&P
4-74
4.31. FUEL PUMP ASSEMBLY.
This task covers:
a. Test
b. Replace
INITIAL SETUP
Tools
General Mechanic's Tool Kit
(Item 1, Appendix B)
Hand Siphon
(Item 22, Appendix B)
Gloves, Chemical and Oil Protective
(Item 34, Appendix B)
Equipment Conditions
MASTER ON-OFF switch on APU control unit set to
OFF.
Engine stopped and allowed to cool completely.
Materials/Parts
Fuel Pump Assembly
TEST
a. Cut wire ties (if applicable).
b. Loosen clamp (6, Figure 4-18) and remove fuel line (7) from fittings (5) on fuel pump assembly (4).
c. Attach one end of a suitable hose to outlet side of fuel pump assembly and place other end in a
container approved to hold diesel fuel.
d. On control panel, position MASTER ON-OFF switch to ON and BATTLE SHORT switch to ON. Fuel
pump should immediately pump fuel into container. If fuel does not pump, replace fuel pump.
WARNING
Ensure that NO IGNITION SOURCE is within 50 feet of
the 10 kW APU. The fuel in this APU is highly
flammable. Do not smoke. Do not splash fuel on hot
components. Failure to heed this warning could result
in serious injury to personnel or DEATH.
WARNING
Avoid fuel contact with skin. Wear protective gloves,
goggles, apron and mask, while disconnecting fuel lines.
Failure to heed this warning could result in serious injury
to personnel or DEATH
NOTE
When disconnecting fuel lines, a suitable container
should be used to catch fuel leaking from disconnected
fuel lines.